{"id":5555,"date":"2021-05-22T20:44:03","date_gmt":"2021-05-22T12:44:03","guid":{"rendered":"https:\/\/www.sinosonics.com\/?page_id=5555"},"modified":"2026-02-19T14:30:54","modified_gmt":"2026-02-19T06:30:54","slug":"homogenizer-faq","status":"publish","type":"page","link":"https:\/\/www.sinosonics.com\/es\/documents\/homogenizer-faq\/","title":{"rendered":"Homogeneizador FAQ"},"content":{"rendered":"<div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1430px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-padding-right:60px;--awb-padding-left:60px;--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-title title fusion-title-1 fusion-sep-none fusion-title-text fusion-title-size-two\"><h2 class=\"fusion-title-heading title-heading-left\" style=\"margin:0;\">Ultrasonic Homogenizer FAQ: Probe Size, Power &amp; Troubleshooting<\/h2><\/div><div class=\"fusion-text fusion-text-1\"><p>Choosing the right ultrasonic homogenizer configuration is critical for achieving consistent cavitation, efficient energy transfer, and reproducible laboratory results. This FAQ guide covers probe size selection based on sample volume, differences between ultrasonic power and intensity, temperature control during sonication, and common troubleshooting issues such as foaming or overheating.<\/p>\n<p>Whether you are using a handheld probe sonicator for small-volume cell disruption or an industrial ultrasonic homogenizer for nanoparticle dispersion, understanding these parameters will significantly improve performance and reliability.<\/p>\n<\/div><style type=\"text\/css\">.fusion-faqs-wrapper #accordian-1 .fusion-panel { border-color:#e2e2e2; }.fusion-faqs-wrapper #accordian-1 .fusion-panel:hover{ border-color: #e2e2e2; }.fusion-accordian #accordian-1 .panel-title a .fa-fusion-box:before{ font-size: 16px;width: 16px;}.fusion-accordian #accordian-1 .panel-title a .fa-fusion-box{ color: #ffffff;}.fusion-accordian  #accordian-1 .panel-title a{font-family:\"Roboto\";font-style:normal;font-weight:regular;}.fusion-accordian  #accordian-1 .panel-title a:not(:hover){}.fusion-accordian  #accordian-1 .toggle-content{font-family:\"Roboto\";font-style:normal;font-weight:400;}.fusion-accordian #accordian-1 .fa-fusion-box { background-color: #212934 !important;border-color: #212934 !important;}.fusion-accordian #accordian-1 .panel-title a:hover,.fusion-accordian #accordian-1 .panel-title a.hover { color: #65bc7b;}.fusion-faq-shortcode .fusion-accordian #accordian-1 .fusion-toggle-boxed-mode:hover .panel-title a { color: #65bc7b;}.fusion-accordian #accordian-1 .panel-title .active .fa-fusion-box,.fusion-accordian #accordian-1 .panel-title a:hover .fa-fusion-box,.fusion-accordian #accordian-1 .panel-title a.hover .fa-fusion-box { background-color: #65bc7b!important;border-color: #65bc7b!important;}<\/style><div class=\"fusion-faq-shortcode\" style=\"\"><div class=\"fusion-faqs-wrapper\"><div class=\"accordian fusion-accordian\"><div class=\"panel-group\" id=\"accordian-1\"><div class=\"fusion-panel panel-default fusion-faq-post fusion-faq-post-5484 ultrasonic-homogenizer\"><span class=\"entry-title rich-snippet-hidden\">What sample volume is suitable for different ultrasonic homogenizer probe sizes?<\/span><span class=\"vcard rich-snippet-hidden\"><span class=\"fn\"><a href=\"https:\/\/www.sinosonics.com\/es\/author\/sino_sonics\/\" title=\"Entradas de Sino_Sonics\" rel=\"author\">Sino_Sonics<\/a><\/span><\/span><span class=\"updated rich-snippet-hidden\">2026-05-05T21:43:04+08:00<\/span><div class=\"panel-heading\"><h4 id=\"faq_1-5484\" class=\"panel-title toggle\"><a data-toggle=\"collapse\" class=\"collapsed\" data-parent=\"#accordian-1\" data-target=\"#collapse-1-5484\" href=\"#collapse-1-5484\" aria-expanded=\"false\"><div class=\"fusion-toggle-icon-wrapper\"><div class=\"fusion-toggle-icon-wrapper-main\"><div class=\"fusion-toggle-icon-wrapper-sub\"><i class=\"fa-fusion-box active-icon awb-icon-minus\" aria-hidden=\"true\"><\/i><i class=\"fa-fusion-box inactive-icon awb-icon-plus\" aria-hidden=\"true\"><\/i><\/div><\/div><\/div><div class=\"fusion-toggle-heading\">What sample volume is suitable for different ultrasonic homogenizer probe sizes?<\/div><\/a><\/h4><\/div><div id=\"collapse-1-5484\" aria-labelledby=\"faq_1-5484\" class=\"panel-collapse collapse\"><div class=\"panel-body toggle-content post-content\"><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1-1 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"width:104% !important;max-width:104% !important;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-1 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-flex-grow:0;--awb-flex-shrink:0;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-flex-grow-medium:0;--awb-flex-shrink-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-flex-grow-small:0;--awb-flex-shrink-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-reading-box-container reading-box-container-1\" style=\"--awb-title-color:#0d244c;--awb-margin-top:0px;--awb-margin-bottom:30px;\"><div class=\"reading-box\" style=\"background-color:#f9f9fb;border-width:1px;border-color:rgba(226,226,226,0);border-style:solid;\"><div class=\"reading-box-additional\">\n<p>Selecting the proper probe size is critical for efficient sonication. As a general guideline, a \u00bd\u201d probe processes approximately 20\u2013250 ml, microtips are recommended for volumes below 50 ml, and a 1\u201d probe is suitable for 1 liter processing. Vessel geometry also matters \u2014 even if 20 ml falls within the \u00bd\u201d range, the probe may not physically fit inside a narrow tube, in which case a microtip is a better option. Small tips generate higher intensity and heat more quickly, so pulse mode is recommended to prevent overheating. For larger volumes, bigger probes improve processing efficiency and reduce time; for volumes above 1 liter, using a stir bar can further increase effectiveness. There is no absolute volume limit for any probe, as final selection depends on material properties and vessel shape.<\/p>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><svg style=\"opacity:0.7;\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" version=\"1.1\" width=\"100%\" viewbox=\"0 0 600 28\" preserveaspectratio=\"none\"><g clip-path=\"url(#a)\"><mask id=\"b\" style=\"mask-type:luminance\" maskunits=\"userSpaceOnUse\" x=\"0\" y=\"0\" width=\"600\" height=\"28\"><path d=\"M0 0h600v28H0V0Z\" fill=\"#fff\"\/><\/mask><g filter=\"url(#c)\" mask=\"url(#b)\"><path d=\"M16.439-18.667h567.123v30.8S438.961-8.4 300-8.4C161.04-8.4 16.438 12.133 16.438 12.133v-30.8Z\" fill=\"#000\"\/><\/g><\/g><defs><clippath id=\"a\"><path fill=\"#fff\" d=\"M0 0h600v28H0z\"\/><\/clippath><filter id=\"c\" x=\"5.438\" y=\"-29.667\" width=\"589.123\" height=\"52.8\" filterunits=\"userSpaceOnUse\" color-interpolation-filters=\"sRGB\"><feflood flood-opacity=\"0\" result=\"BackgroundImageFix\"\/><feblend in=\"SourceGraphic\" in2=\"BackgroundImageFix\" result=\"shape\"\/><fegaussianblur stddeviation=\"5.5\" result=\"effect1_foregroundBlur_3983_183\"\/><\/filter><\/defs><\/svg><\/div>\n<div class=\"table-1\">\n<table width=\"100%\">\n<thead>\n<tr>\n<th align=\"left\">Probe Tip<br \/>\nDiameter<\/th>\n<th align=\"left\">Process<br \/>\nVolume Range<\/th>\n<th align=\"left\">Amplitude<br \/>\nMicrons<\/th>\n<th align=\"left\">Probe<br \/>\nLength<\/th>\n<th align=\"left\">Materials<br \/>\nfinal size<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td align=\"left\"><span style=\"color: #000000;\">1\/16&#8243; (1.6 mm)<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">0.2 ml ~ 15 ml<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">320 \u03bcm<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">9 cm<\/span><\/td>\n<td align=\"left\">2 ~3 nanometer<\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><span style=\"color: #000000;\">1\/8&#8243; (3.2 mm)<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">0.5 ml ~ 25 ml<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">180 \u03bcm<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">14 cm<\/span><\/td>\n<td align=\"left\">3 nanometer<\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><span style=\"color: #000000;\">1\/4&#8243; (6.4 mm)<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">10 ml ~ 100 ml<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">120 \u03bcm<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">11 cm<\/span><\/td>\n<td align=\"left\">3 nanometer<\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><span style=\"color: #000000;\">8.0 mm<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">10 ml ~ 200 ml<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">100 \u03bcm<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">11 cm<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">3 nanometer<\/span><\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><span style=\"color: #000000;\">9.0 mm<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">10 ml ~ 250 ml<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">90 \u03bcm<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">10 cm<\/span><\/td>\n<td align=\"left\">4 nanometer<\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><span style=\"color: #000000;\">10.0 mm<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">20 ml ~ 300 ml<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">80 \u03bcm<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">10 cm<\/span><\/td>\n<td align=\"left\">4 nanometer<\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><span style=\"color: #000000;\">1\/2&#8243; (12.7mm)<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">20 ml ~ 300 ml<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">60 ~ 120 \u03bcm<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">13 cm<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">3 ~5 nanometer<\/span><\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><span style=\"color: #000000;\">16.0 mm<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">20 ml ~ 600 ml<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">70<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">13 cm<\/span><\/td>\n<td align=\"left\">5 nanometer<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">3\/4&#8243; (19.1mm)<\/td>\n<td align=\"left\">50 ml ~ 800 ml<\/td>\n<td align=\"left\">60 \u03bcm<\/td>\n<td align=\"left\">28 cm<\/td>\n<td align=\"left\">5 nanometer<\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><span style=\"color: #000000;\">20.0 mm<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">50 ml ~ 900 ml<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">55 ~80 \u03bcm<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">28 cm<\/span><\/td>\n<td align=\"left\">7 nanometer<\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><span style=\"color: #000000;\">1&#8243; (25.4mm)<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">100 ml ~ 1000 ml<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">35 \u03bcm<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">28 cm<\/span><\/td>\n<td align=\"left\">7 nanometer<\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><span style=\"color: #000000;\">30.0 mm<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">100 ml ~ 3 litre<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">35 \u03bcm<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">30 cm<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">8 nanometer<\/span><\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><span style=\"color: #000000;\">40.0 mm<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">1000 ml ~ 25 litre<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">25 \u03bcm<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">30 cm<\/span><\/td>\n<td align=\"left\">10 nanometer<\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><span style=\"color: #000000;\">50.0 mm<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">\u00a01000 ml ~ 30 litre<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">30 \u03bcm<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">50 cm<\/span><\/td>\n<td align=\"left\"><span style=\"color: #000000;\">10 nanometer<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"fusion-text fusion-text-2\" style=\"--awb-margin-top:20px;\"><p><em>* Depends on the frequency &amp; probe design, the vibration amplitude will also change accordingly. however, the principle &amp; philosophy is same.<\/em><br \/>\n<em>* The processed material&#8217;s final size depends on the processing duration time, and material&#8217;s characteristics &amp; propertites.<\/em><br \/>\n<em>* The probe length &amp; total length will be different according to frequency &amp; design.<\/em><br \/>\n<em>* The probe length &amp; tip diameter are all customizable.<\/em><\/p>\n<\/div><\/div><\/div><\/div><\/div>\n<\/div><\/div><\/div><div class=\"fusion-panel panel-default fusion-faq-post fusion-faq-post-5530 ultrasonic-homogenizer\"><span class=\"entry-title rich-snippet-hidden\">What is the difference between ultrasonic power and intensity?<\/span><span class=\"vcard rich-snippet-hidden\"><span class=\"fn\"><a href=\"https:\/\/www.sinosonics.com\/es\/author\/sino_sonics\/\" title=\"Entradas de Sino_Sonics\" rel=\"author\">Sino_Sonics<\/a><\/span><\/span><span class=\"updated rich-snippet-hidden\">2026-02-19T13:21:09+08:00<\/span><div class=\"panel-heading\"><h4 id=\"faq_1-5530\" class=\"panel-title toggle\"><a data-toggle=\"collapse\" class=\"collapsed\" data-parent=\"#accordian-1\" data-target=\"#collapse-1-5530\" href=\"#collapse-1-5530\" aria-expanded=\"false\"><div class=\"fusion-toggle-icon-wrapper\"><div class=\"fusion-toggle-icon-wrapper-main\"><div class=\"fusion-toggle-icon-wrapper-sub\"><i class=\"fa-fusion-box active-icon awb-icon-minus\" aria-hidden=\"true\"><\/i><i class=\"fa-fusion-box inactive-icon awb-icon-plus\" aria-hidden=\"true\"><\/i><\/div><\/div><\/div><div class=\"fusion-toggle-heading\">What is the difference between ultrasonic power and intensity?<\/div><\/a><\/h4><\/div><div id=\"collapse-1-5530\" aria-labelledby=\"faq_1-5530\" class=\"panel-collapse collapse\"><div class=\"panel-body toggle-content post-content\"><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1-2 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-stretch fusion-flex-content-wrap\" style=\"width:104% !important;max-width:104% !important;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-2 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-padding-right:0px;--awb-padding-left:0px;--awb-bg-size:cover;--awb-width-large:100%;--awb-flex-grow:0;--awb-flex-shrink:0;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-flex-grow-medium:0;--awb-flex-shrink-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-flex-grow-small:0;--awb-flex-shrink-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-reading-box-container reading-box-container-2\" style=\"--awb-title-color:#0d244c;--awb-margin-top:0px;--awb-margin-bottom:30px;\"><div class=\"reading-box\" style=\"background-color:#f9f9fb;border-width:1px;border-color:rgba(226,226,226,0);border-style:solid;\"><div class=\"reading-box-additional\">\n<p>Power is the electrical energy delivered to the converter and displayed in watts, while intensity is directly related to amplitude \u2014 the actual mechanical vibration of the probe tip. Amplitude determines how aggressively the sample is processed, and it is the most critical parameter for reproducible results. For example, a \u00bd\u201d probe at 100% may reach approximately 120 \u03bcm amplitude, and at 50% around 60 \u03bcm. Power consumption, however, varies depending on sample viscosity and load \u2014 a viscous sample requires more watts even at the same amplitude. Therefore, consistent sonication results depend primarily on maintaining stable amplitude, temperature, and sample conditions rather than focusing solely on wattage readings.<\/p>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div><\/div><\/div>\n<\/div><\/div><\/div><div class=\"fusion-panel panel-default fusion-faq-post fusion-faq-post-5539 ultrasonic-homogenizer\"><span class=\"entry-title rich-snippet-hidden\">How to control temperature during ultrasonic homogenization?<\/span><span class=\"vcard rich-snippet-hidden\"><span class=\"fn\"><a href=\"https:\/\/www.sinosonics.com\/es\/author\/sino_sonics\/\" title=\"Entradas de Sino_Sonics\" rel=\"author\">Sino_Sonics<\/a><\/span><\/span><span class=\"updated rich-snippet-hidden\">2026-02-19T13:22:52+08:00<\/span><div class=\"panel-heading\"><h4 id=\"faq_1-5539\" class=\"panel-title toggle\"><a data-toggle=\"collapse\" class=\"collapsed\" data-parent=\"#accordian-1\" data-target=\"#collapse-1-5539\" href=\"#collapse-1-5539\" aria-expanded=\"false\"><div class=\"fusion-toggle-icon-wrapper\"><div class=\"fusion-toggle-icon-wrapper-main\"><div class=\"fusion-toggle-icon-wrapper-sub\"><i class=\"fa-fusion-box active-icon awb-icon-minus\" aria-hidden=\"true\"><\/i><i class=\"fa-fusion-box inactive-icon awb-icon-plus\" aria-hidden=\"true\"><\/i><\/div><\/div><\/div><div class=\"fusion-toggle-heading\">How to control temperature during ultrasonic homogenization?<\/div><\/a><\/h4><\/div><div id=\"collapse-1-5539\" aria-labelledby=\"faq_1-5539\" class=\"panel-collapse collapse\"><div class=\"panel-body toggle-content post-content\"><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1-3 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-stretch fusion-flex-content-wrap\" style=\"width:104% !important;max-width:104% !important;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-3 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-padding-right:0px;--awb-padding-left:0px;--awb-bg-size:cover;--awb-width-large:100%;--awb-flex-grow:0;--awb-flex-shrink:0;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-flex-grow-medium:0;--awb-flex-shrink-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-flex-grow-small:0;--awb-flex-shrink-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-reading-box-container reading-box-container-3\" style=\"--awb-title-color:#0d244c;--awb-margin-top:0px;--awb-margin-bottom:30px;\"><div class=\"reading-box\" style=\"background-color:#f9f9fb;border-width:1px;border-color:rgba(226,226,226,0);border-style:solid;\"><div class=\"reading-box-additional\">\n<p>Temperature rise during sonication is caused by energy dissipation from cavitation and mechanical vibration. Excessive heat can denature proteins, degrade sensitive materials, or alter reaction conditions, so temperature control is critical for reproducible results. Effective cooling methods include using pulse mode to reduce continuous energy input, combining pulse mode with an ice bath, using CoolRack systems to stabilize and chill samples, or employing external chillers for higher power applications. Standard probes are approved for liquid temperatures up to 140\u00b0F (60\u00b0C), but maintaining lower temperatures is recommended for heat-sensitive samples.<\/p>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div><\/div><\/div>\n<\/div><\/div><\/div><div class=\"fusion-panel panel-default fusion-faq-post fusion-faq-post-5519 ultrasonic-homogenizer\"><span class=\"entry-title rich-snippet-hidden\">How to prevent foaming during ultrasonic homogenization?<\/span><span class=\"vcard rich-snippet-hidden\"><span class=\"fn\"><a href=\"https:\/\/www.sinosonics.com\/es\/author\/sino_sonics\/\" title=\"Entradas de Sino_Sonics\" rel=\"author\">Sino_Sonics<\/a><\/span><\/span><span class=\"updated rich-snippet-hidden\">2026-02-19T13:43:41+08:00<\/span><div class=\"panel-heading\"><h4 id=\"faq_1-5519\" class=\"panel-title toggle\"><a data-toggle=\"collapse\" class=\"collapsed\" data-parent=\"#accordian-1\" data-target=\"#collapse-1-5519\" href=\"#collapse-1-5519\" aria-expanded=\"false\"><div class=\"fusion-toggle-icon-wrapper\"><div class=\"fusion-toggle-icon-wrapper-main\"><div class=\"fusion-toggle-icon-wrapper-sub\"><i class=\"fa-fusion-box active-icon awb-icon-minus\" aria-hidden=\"true\"><\/i><i class=\"fa-fusion-box inactive-icon awb-icon-plus\" aria-hidden=\"true\"><\/i><\/div><\/div><\/div><div class=\"fusion-toggle-heading\">How to prevent foaming during ultrasonic homogenization?<\/div><\/a><\/h4><\/div><div id=\"collapse-1-5519\" aria-labelledby=\"faq_1-5519\" class=\"panel-collapse collapse\"><div class=\"panel-body toggle-content post-content\"><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1-4 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-stretch fusion-flex-content-wrap\" style=\"width:104% !important;max-width:104% !important;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-4 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-flex-grow:0;--awb-flex-shrink:0;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-flex-grow-medium:0;--awb-flex-shrink-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-flex-grow-small:0;--awb-flex-shrink-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-reading-box-container reading-box-container-4\" style=\"--awb-title-color:#0d244c;--awb-margin-top:0px;--awb-margin-bottom:30px;\"><div class=\"reading-box\" style=\"background-color:#f9f9fb;border-width:1px;border-color:rgba(226,226,226,0);border-style:solid;\"><div class=\"reading-box-additional\">\n<div class=\"grid__item\">\n<p>Probes must be submerged at the correct depth to ensure proper cavitation and sample circulation. If the tip is positioned too close to the surface, air will be drawn into the liquid, causing foaming and poor processing efficiency. If the tip is inserted too deeply, circulation becomes restricted and energy distribution is reduced. Both situations can negatively affect results. Foaming is more common in small volumes (below 1 mL) and when amplitude settings are excessively high.<\/p>\n<\/div>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-5 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:50%;--awb-flex-grow:0;--awb-flex-shrink:0;--awb-margin-top-large:0px;--awb-spacing-right-large:3.84%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:3.84%;--awb-width-medium:50%;--awb-order-medium:0;--awb-flex-grow-medium:0;--awb-flex-shrink-medium:0;--awb-spacing-right-medium:3.84%;--awb-spacing-left-medium:3.84%;--awb-width-small:100%;--awb-order-small:0;--awb-flex-grow-small:0;--awb-flex-shrink-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-image-element\" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\"fusion-imageframe imageframe-none imageframe-1 hover-type-none\" style=\"border-radius:6px;\"><img decoding=\"async\" width=\"1024\" height=\"830\" alt=\"Ultrasonic homogenizer probe tip depth diagram showing correct and incorrect insertion positions to prevent foaming\" title=\"Ultrasonic Homogenizer Tip Depth Diagram\" src=\"https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-a-beaker-assyrev-1024x830.jpg\" class=\"img-responsive wp-image-5520\" srcset=\"https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-a-beaker-assyrev-200x162.jpg 200w, https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-a-beaker-assyrev-400x324.jpg 400w, https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-a-beaker-assyrev-600x487.jpg 600w, https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-a-beaker-assyrev-800x649.jpg 800w, https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-a-beaker-assyrev-1200x973.jpg 1200w\" sizes=\"(max-width: 640px) 100vw, 800px\" \/><\/span><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-6 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:50%;--awb-flex-grow:0;--awb-flex-shrink:0;--awb-margin-top-large:0px;--awb-spacing-right-large:3.84%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:3.84%;--awb-width-medium:50%;--awb-order-medium:0;--awb-flex-grow-medium:0;--awb-flex-shrink-medium:0;--awb-spacing-right-medium:3.84%;--awb-spacing-left-medium:3.84%;--awb-width-small:100%;--awb-order-small:0;--awb-flex-grow-small:0;--awb-flex-shrink-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-image-element\" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\"fusion-imageframe imageframe-none imageframe-2 hover-type-none\" style=\"border-radius:6px;\"><img decoding=\"async\" width=\"1024\" height=\"824\" alt=\"Ultrasonic microtip insertion depth in microcentrifuge tube showing incorrect shallow (A), incorrect deep (B), and correct position (C)\" title=\"Ultrasonic Microtip Insertion Depth Diagram\" src=\"https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-a-q-tubewater-1024x824.jpg\" class=\"img-responsive wp-image-5521\" srcset=\"https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-a-q-tubewater-200x161.jpg 200w, https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-a-q-tubewater-400x322.jpg 400w, https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-a-q-tubewater-600x483.jpg 600w, https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-a-q-tubewater-800x644.jpg 800w, https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-a-q-tubewater-1200x965.jpg 1200w, https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-a-q-tubewater.jpg 1708w\" sizes=\"(max-width: 640px) 100vw, 800px\" \/><\/span><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-7 fusion_builder_column_3_4 3_4 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:75%;--awb-flex-grow:0;--awb-flex-shrink:0;--awb-margin-top-large:0px;--awb-spacing-right-large:2.56%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:2.56%;--awb-width-medium:75%;--awb-order-medium:0;--awb-flex-grow-medium:0;--awb-flex-shrink-medium:0;--awb-spacing-right-medium:2.56%;--awb-spacing-left-medium:2.56%;--awb-width-small:100%;--awb-order-small:0;--awb-flex-grow-small:0;--awb-flex-shrink-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-reading-box-container reading-box-container-5\" style=\"--awb-title-color:#0d244c;--awb-margin-top:0px;--awb-margin-bottom:30px;\"><div class=\"reading-box\" style=\"background-color:#f9f9fb;border-width:1px;border-color:rgba(226,226,226,0);border-style:solid;\"><div class=\"reading-box-additional\">\n<p data-start=\"809\" data-end=\"1091\">As illustrated above, Figure A introduces air and causes foam formation, resulting in inefficient processing. Figure B limits fluid circulation and reduces cavitation efficiency. Figure C represents the optimal setup, allowing effective energy transfer and faster processing time.<\/p>\n<p data-start=\"1093\" data-end=\"1402\">When tubes are placed in ice baths for temperature control, the liquid level can be difficult to observe. To maintain consistent positioning, we recommend marking the correct insertion depth on the probe with a permanent marker. This ensures reproducible tip placement, even when the tube is submerged in ice.<\/p>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-8 fusion_builder_column_1_4 1_4 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:25%;--awb-flex-grow:0;--awb-flex-shrink:0;--awb-margin-top-large:0px;--awb-spacing-right-large:7.68%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:7.68%;--awb-width-medium:25%;--awb-order-medium:0;--awb-flex-grow-medium:0;--awb-flex-shrink-medium:0;--awb-spacing-right-medium:7.68%;--awb-spacing-left-medium:7.68%;--awb-width-small:100%;--awb-order-small:0;--awb-flex-grow-small:0;--awb-flex-shrink-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-image-element\" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\"fusion-imageframe imageframe-none imageframe-3 hover-type-none\" style=\"border-radius:6px;\"><img decoding=\"async\" width=\"710\" height=\"720\" alt=\"Ultrasonic microtip inserted to correct depth in a small tube, red line marking optimal immersion level\" title=\"Ultrasonic Microtip Correct Insertion Depth\" src=\"https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-microtip-line-v2.jpg\" class=\"img-responsive wp-image-5522\" srcset=\"https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-microtip-line-v2-200x203.jpg 200w, https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-microtip-line-v2-400x406.jpg 400w, https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-microtip-line-v2-600x608.jpg 600w, https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-microtip-line-v2.jpg 710w\" sizes=\"(max-width: 640px) 100vw, 400px\" \/><\/span><\/div><\/div><\/div><\/div><\/div>\n<\/div><\/div><\/div><div class=\"fusion-panel panel-default fusion-faq-post fusion-faq-post-5547 ultrasonic-homogenizer\"><span class=\"entry-title rich-snippet-hidden\">How to calculate the energy delivered during ultrasonic sonication?<\/span><span class=\"vcard rich-snippet-hidden\"><span class=\"fn\"><a href=\"https:\/\/www.sinosonics.com\/es\/author\/sino_sonics\/\" title=\"Entradas de Sino_Sonics\" rel=\"author\">Sino_Sonics<\/a><\/span><\/span><span class=\"updated rich-snippet-hidden\">2026-02-19T13:47:09+08:00<\/span><div class=\"panel-heading\"><h4 id=\"faq_1-5547\" class=\"panel-title toggle\"><a data-toggle=\"collapse\" class=\"collapsed\" data-parent=\"#accordian-1\" data-target=\"#collapse-1-5547\" href=\"#collapse-1-5547\" aria-expanded=\"false\"><div class=\"fusion-toggle-icon-wrapper\"><div class=\"fusion-toggle-icon-wrapper-main\"><div class=\"fusion-toggle-icon-wrapper-sub\"><i class=\"fa-fusion-box active-icon awb-icon-minus\" aria-hidden=\"true\"><\/i><i class=\"fa-fusion-box inactive-icon awb-icon-plus\" aria-hidden=\"true\"><\/i><\/div><\/div><\/div><div class=\"fusion-toggle-heading\">How to calculate the energy delivered during ultrasonic sonication?<\/div><\/a><\/h4><\/div><div id=\"collapse-1-5547\" aria-labelledby=\"faq_1-5547\" class=\"panel-collapse collapse\"><div class=\"panel-body toggle-content post-content\"><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1-5 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-stretch fusion-flex-content-wrap\" style=\"width:104% !important;max-width:104% !important;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-9 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-padding-right:0px;--awb-padding-left:0px;--awb-bg-size:cover;--awb-width-large:100%;--awb-flex-grow:0;--awb-flex-shrink:0;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-flex-grow-medium:0;--awb-flex-shrink-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-flex-grow-small:0;--awb-flex-shrink-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-reading-box-container reading-box-container-6\" style=\"--awb-title-color:#0d244c;--awb-margin-top:0px;--awb-margin-bottom:30px;\"><div class=\"reading-box\" style=\"background-color:#f9f9fb;border-width:1px;border-color:rgba(226,226,226,0);border-style:solid;\"><div class=\"reading-box-additional\">\n<p data-start=\"950\" data-end=\"1192\">The watts displayed on the generator screen represent the electrical power delivered to the converter. However, not all of this power is transferred into the sample. The actual energy delivered depends on load conditions and probe resistance.<\/p>\n<p data-start=\"1194\" data-end=\"1240\">To estimate the power delivered to the sample:<\/p>\n<ol data-start=\"1242\" data-end=\"1580\">\n<li data-start=\"1242\" data-end=\"1269\">\n<p data-start=\"1245\" data-end=\"1269\">Turn on the equipment.<\/p>\n<\/li>\n<li data-start=\"1270\" data-end=\"1301\">\n<p data-start=\"1273\" data-end=\"1301\">Set the desired amplitude.<\/p>\n<\/li>\n<li data-start=\"1302\" data-end=\"1371\">\n<p data-start=\"1305\" data-end=\"1371\">With the probe in air (no sample), record the wattage displayed.<\/p>\n<\/li>\n<li data-start=\"1372\" data-end=\"1466\">\n<p data-start=\"1375\" data-end=\"1466\">Without changing amplitude, immerse the probe into the sample and record the new wattage.<\/p>\n<\/li>\n<li data-start=\"1467\" data-end=\"1580\">\n<p data-start=\"1470\" data-end=\"1580\">The difference between these two readings represents the approximate power delivered to the sample (in watts).<\/p>\n<\/li>\n<\/ol>\n<p data-start=\"1582\" data-end=\"1639\">To calculate ultrasonic intensity (power density, W\/cm\u00b2):<\/p>\n<p data-start=\"1641\" data-end=\"1695\">Intensity = Power delivered (W) \u00f7 Probe tip area (cm\u00b2)<\/p>\n<p data-start=\"1697\" data-end=\"1729\">Probe tip area is calculated as:<\/p>\n<p data-start=\"1731\" data-end=\"1778\">Area = \u03c0 \u00d7 r\u00b2<br data-start=\"1744\" data-end=\"1747\" \/>or<br data-start=\"1749\" data-end=\"1752\" \/>Area = \u03c0 \u00d7 (diameter \/ 2)\u00b2<\/p>\n<p data-start=\"1780\" data-end=\"1807\">Example using a 3 mm probe:<\/p>\n<p data-start=\"1809\" data-end=\"1854\">Diameter = 3 mm = 0.3 cm<br data-start=\"1833\" data-end=\"1836\" \/>Radius = 0.15 cm<\/p>\n<p data-start=\"1856\" data-end=\"1906\">Area = \u03c0 \u00d7 (0.15)\u00b2 = 3.142 \u00d7 0.0225 = 0.0707 cm\u00b2<\/p>\n<p data-start=\"1908\" data-end=\"1945\">If 1 watt is delivered to the sample:<\/p>\n<p data-start=\"1947\" data-end=\"1985\">Intensity = 1 \u00f7 0.0707 = 14.14 W\/cm\u00b2<\/p>\n<p data-start=\"1987\" data-end=\"2119\">Note: This method provides an approximate estimation of ultrasonic intensity and does not account for acoustic losses in the liquid.<\/p>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div><\/div><\/div>\n<\/div><\/div><\/div><div class=\"fusion-panel panel-default fusion-faq-post fusion-faq-post-5536 ultrasonic-homogenizer\"><span class=\"entry-title rich-snippet-hidden\">How to optimize ultrasonic homogenizer settings for better performance?<\/span><span class=\"vcard rich-snippet-hidden\"><span class=\"fn\"><a href=\"https:\/\/www.sinosonics.com\/es\/author\/sino_sonics\/\" title=\"Entradas de Sino_Sonics\" rel=\"author\">Sino_Sonics<\/a><\/span><\/span><span class=\"updated rich-snippet-hidden\">2026-02-19T13:49:47+08:00<\/span><div class=\"panel-heading\"><h4 id=\"faq_1-5536\" class=\"panel-title toggle\"><a data-toggle=\"collapse\" class=\"collapsed\" data-parent=\"#accordian-1\" data-target=\"#collapse-1-5536\" href=\"#collapse-1-5536\" aria-expanded=\"false\"><div class=\"fusion-toggle-icon-wrapper\"><div class=\"fusion-toggle-icon-wrapper-main\"><div class=\"fusion-toggle-icon-wrapper-sub\"><i class=\"fa-fusion-box active-icon awb-icon-minus\" aria-hidden=\"true\"><\/i><i class=\"fa-fusion-box inactive-icon awb-icon-plus\" aria-hidden=\"true\"><\/i><\/div><\/div><\/div><div class=\"fusion-toggle-heading\">How to optimize ultrasonic homogenizer settings for better performance?<\/div><\/a><\/h4><\/div><div id=\"collapse-1-5536\" aria-labelledby=\"faq_1-5536\" class=\"panel-collapse collapse\"><div class=\"panel-body toggle-content post-content\"><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1-6 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-stretch fusion-flex-content-wrap\" style=\"width:104% !important;max-width:104% !important;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-10 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-padding-right:0px;--awb-padding-left:0px;--awb-bg-size:cover;--awb-width-large:100%;--awb-flex-grow:0;--awb-flex-shrink:0;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-flex-grow-medium:0;--awb-flex-shrink-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-flex-grow-small:0;--awb-flex-shrink-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-reading-box-container reading-box-container-7\" style=\"--awb-title-color:#0d244c;--awb-margin-top:0px;--awb-margin-bottom:30px;\"><div class=\"reading-box\" style=\"background-color:#f9f9fb;border-width:1px;border-color:rgba(226,226,226,0);border-style:solid;\"><div class=\"reading-box-additional\">\n<p data-start=\"692\" data-end=\"818\">Ultrasonic homogenization requires optimization of amplitude, pulse mode, and processing time to achieve reproducible results.<\/p>\n<ol data-start=\"820\" data-end=\"1864\">\n<li data-start=\"820\" data-end=\"1101\">\n<p data-start=\"823\" data-end=\"1101\">Start by testing your probe in water using the same volume and vessel geometry as your actual application. Observe cavitation behavior and liquid circulation at different amplitude settings. Proper cavitation should produce uniform mixing without excessive foaming or splashing.<\/p>\n<\/li>\n<li data-start=\"1103\" data-end=\"1390\">\n<p data-start=\"1106\" data-end=\"1390\">Select an amplitude that provides effective cavitation without overheating or sample degradation. Smaller volumes typically require lower amplitude and shorter pulse cycles to control temperature rise. Larger volumes may require higher amplitude to maintain sufficient energy density.<\/p>\n<\/li>\n<li data-start=\"1392\" data-end=\"1645\">\n<p data-start=\"1395\" data-end=\"1645\">Perform a time study. Process identical samples at different time intervals and evaluate particle size, dispersion quality, or cell disruption efficiency. Adjust amplitude and duration based on measurable results rather than visual observation alone.<\/p>\n<\/li>\n<li data-start=\"1647\" data-end=\"1864\">\n<p data-start=\"1650\" data-end=\"1864\">For advanced applications (e.g., nanoparticle dispersion, emulsification, cell lysis), optimization should consider energy density (W\/cm\u00b2), total energy input (J), and temperature profile to ensure reproducibility.<\/p>\n<\/li>\n<\/ol>\n<p data-start=\"1866\" data-end=\"1944\">Validated parameter ranges for common applications are available upon request.<\/p>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div><\/div><\/div>\n<\/div><\/div><\/div><div class=\"fusion-panel panel-default fusion-faq-post fusion-faq-post-5534 ultrasonic-homogenizer\"><span class=\"entry-title rich-snippet-hidden\">What probe size is recommended for nanoparticle dispersion?<\/span><span class=\"vcard rich-snippet-hidden\"><span class=\"fn\"><a href=\"https:\/\/www.sinosonics.com\/es\/author\/sino_sonics\/\" title=\"Entradas de Sino_Sonics\" rel=\"author\">Sino_Sonics<\/a><\/span><\/span><span class=\"updated rich-snippet-hidden\">2026-02-19T13:50:41+08:00<\/span><div class=\"panel-heading\"><h4 id=\"faq_1-5534\" class=\"panel-title toggle\"><a data-toggle=\"collapse\" class=\"collapsed\" data-parent=\"#accordian-1\" data-target=\"#collapse-1-5534\" href=\"#collapse-1-5534\" aria-expanded=\"false\"><div class=\"fusion-toggle-icon-wrapper\"><div class=\"fusion-toggle-icon-wrapper-main\"><div class=\"fusion-toggle-icon-wrapper-sub\"><i class=\"fa-fusion-box active-icon awb-icon-minus\" aria-hidden=\"true\"><\/i><i class=\"fa-fusion-box inactive-icon awb-icon-plus\" aria-hidden=\"true\"><\/i><\/div><\/div><\/div><div class=\"fusion-toggle-heading\">What probe size is recommended for nanoparticle dispersion?<\/div><\/a><\/h4><\/div><div id=\"collapse-1-5534\" aria-labelledby=\"faq_1-5534\" class=\"panel-collapse collapse\"><div class=\"panel-body toggle-content post-content\"><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1-7 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-stretch fusion-flex-content-wrap\" style=\"width:104% !important;max-width:104% !important;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-11 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-padding-right:0px;--awb-padding-left:0px;--awb-bg-size:cover;--awb-width-large:100%;--awb-flex-grow:0;--awb-flex-shrink:0;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-flex-grow-medium:0;--awb-flex-shrink-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-flex-grow-small:0;--awb-flex-shrink-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-reading-box-container reading-box-container-8\" style=\"--awb-title-color:#0d244c;--awb-margin-top:0px;--awb-margin-bottom:30px;\"><div class=\"reading-box\" style=\"background-color:#f9f9fb;border-width:1px;border-color:rgba(226,226,226,0);border-style:solid;\"><div class=\"reading-box-additional\">\n<p data-start=\"586\" data-end=\"819\">Nanoparticle dispersion typically requires high energy density and sufficient processing time to break particle agglomerates effectively. Probe selection should be based on sample volume and required intensity rather than size alone.<\/p>\n<p data-start=\"821\" data-end=\"1097\">For small-volume nanoparticle suspensions (e.g., 5\u201350 mL), smaller diameter probes (3\u20138 mm) often provide higher localized energy density, which improves deagglomeration efficiency. However, they may generate faster temperature rise and tip erosion during extended processing.<\/p>\n<p data-start=\"1099\" data-end=\"1371\">For medium to larger volumes (\u226550 mL), larger diameter probes (12\u201320 mm) allow more uniform energy distribution and improved processing efficiency. Larger probes are also mechanically more robust and typically exhibit slower wear during long-duration dispersion processes.<\/p>\n<p data-start=\"1373\" data-end=\"1420\">In practice, optimal probe size should balance:<\/p>\n<ul data-start=\"1422\" data-end=\"1539\">\n<li data-start=\"1422\" data-end=\"1446\">\n<p data-start=\"1424\" data-end=\"1446\">Energy density (W\/cm\u00b2)<\/p>\n<\/li>\n<li data-start=\"1447\" data-end=\"1471\">\n<p data-start=\"1449\" data-end=\"1471\">Total energy input (J)<\/p>\n<\/li>\n<li data-start=\"1472\" data-end=\"1487\">\n<p data-start=\"1474\" data-end=\"1487\">Sample volume<\/p>\n<\/li>\n<li data-start=\"1488\" data-end=\"1509\">\n<p data-start=\"1490\" data-end=\"1509\">Temperature control<\/p>\n<\/li>\n<li data-start=\"1510\" data-end=\"1539\">\n<p data-start=\"1512\" data-end=\"1539\">Desired final particle size<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"1541\" data-end=\"1656\">Application-specific parameter optimization is recommended to achieve reproducible nanoparticle dispersion results.<\/p>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div><\/div><\/div>\n<\/div><\/div><\/div><div class=\"fusion-panel panel-default fusion-faq-post fusion-faq-post-5525 ultrasonic-homogenizer\"><span class=\"entry-title rich-snippet-hidden\">Does vessel shape and size affect ultrasonic homogenization efficiency?<\/span><span class=\"vcard rich-snippet-hidden\"><span class=\"fn\"><a href=\"https:\/\/www.sinosonics.com\/es\/author\/sino_sonics\/\" title=\"Entradas de Sino_Sonics\" rel=\"author\">Sino_Sonics<\/a><\/span><\/span><span class=\"updated rich-snippet-hidden\">2026-02-19T13:53:31+08:00<\/span><div class=\"panel-heading\"><h4 id=\"faq_1-5525\" class=\"panel-title toggle\"><a data-toggle=\"collapse\" class=\"collapsed\" data-parent=\"#accordian-1\" data-target=\"#collapse-1-5525\" href=\"#collapse-1-5525\" aria-expanded=\"false\"><div class=\"fusion-toggle-icon-wrapper\"><div class=\"fusion-toggle-icon-wrapper-main\"><div class=\"fusion-toggle-icon-wrapper-sub\"><i class=\"fa-fusion-box active-icon awb-icon-minus\" aria-hidden=\"true\"><\/i><i class=\"fa-fusion-box inactive-icon awb-icon-plus\" aria-hidden=\"true\"><\/i><\/div><\/div><\/div><div class=\"fusion-toggle-heading\">Does vessel shape and size affect ultrasonic homogenization efficiency?<\/div><\/a><\/h4><\/div><div id=\"collapse-1-5525\" aria-labelledby=\"faq_1-5525\" class=\"panel-collapse collapse\"><div class=\"panel-body toggle-content post-content\"><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1-8 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-stretch fusion-flex-content-wrap\" style=\"width:104% !important;max-width:104% !important;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-12 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-padding-right:0px;--awb-padding-left:0px;--awb-bg-size:cover;--awb-width-large:50%;--awb-flex-grow:0;--awb-flex-shrink:0;--awb-margin-top-large:0px;--awb-spacing-right-large:3.84%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:3.84%;--awb-width-medium:50%;--awb-order-medium:0;--awb-flex-grow-medium:0;--awb-flex-shrink-medium:0;--awb-spacing-right-medium:3.84%;--awb-spacing-left-medium:3.84%;--awb-width-small:100%;--awb-order-small:0;--awb-flex-grow-small:0;--awb-flex-shrink-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-reading-box-container reading-box-container-9\" style=\"--awb-title-color:#0d244c;--awb-margin-top:0px;--awb-margin-bottom:30px;\"><div class=\"reading-box\" style=\"background-color:#f9f9fb;border-width:1px;border-color:rgba(226,226,226,0);border-style:solid;\"><div class=\"reading-box-additional\">\n<p data-start=\"624\" data-end=\"846\">Vessel geometry significantly influences ultrasonic homogenization efficiency. Ultrasonic energy is generated at the probe tip and propagates downward, creating axial flow and radial circulation patterns within the liquid.<\/p>\n<p data-start=\"848\" data-end=\"1198\">Tall, narrow vessels generally promote more efficient energy distribution because the downward flow and upward recirculation are confined, allowing better mixing of the entire sample volume. In wide vessels, the circulation path becomes longer and energy density decreases toward the periphery, which may result in incomplete processing at the edges.<\/p>\n<p data-start=\"1200\" data-end=\"1224\">For optimal performance:<\/p>\n<ul data-start=\"1226\" data-end=\"1475\">\n<li data-start=\"1226\" data-end=\"1291\">\n<p data-start=\"1228\" data-end=\"1291\">Use a vessel diameter slightly larger than the probe diameter<\/p>\n<\/li>\n<li data-start=\"1292\" data-end=\"1349\">\n<p data-start=\"1294\" data-end=\"1349\">Maintain sufficient liquid height above the probe tip<\/p>\n<\/li>\n<li data-start=\"1350\" data-end=\"1405\">\n<p data-start=\"1352\" data-end=\"1405\">Avoid excessively wide containers for small volumes<\/p>\n<\/li>\n<li data-start=\"1406\" data-end=\"1475\">\n<p data-start=\"1408\" data-end=\"1475\">Ensure the probe does not touch the sides or bottom of the vessel<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"1477\" data-end=\"1590\">Proper vessel selection improves mixing efficiency, reduces processing time, and enhances result reproducibility.<\/p>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-13 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-padding-right:0px;--awb-padding-left:0px;--awb-bg-size:cover;--awb-width-large:50%;--awb-flex-grow:0;--awb-flex-shrink:0;--awb-margin-top-large:0px;--awb-spacing-right-large:3.84%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:3.84%;--awb-width-medium:50%;--awb-order-medium:0;--awb-flex-grow-medium:0;--awb-flex-shrink-medium:0;--awb-spacing-right-medium:3.84%;--awb-spacing-left-medium:3.84%;--awb-width-small:100%;--awb-order-small:0;--awb-flex-grow-small:0;--awb-flex-shrink-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-image-element\" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\"fusion-imageframe imageframe-none imageframe-4 hover-type-none\" style=\"border-radius:6px;\"><img decoding=\"async\" width=\"1024\" height=\"853\" alt=\"Correct vessel shape for ultrasonic homogenizer probe \u2013 narrow vessel improves mixing efficiency compared to wide container\" title=\"Ultrasonic Homogenizer Vessel Shape Comparison\" src=\"https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-a-beaker-assy1-1024x853.jpg\" class=\"img-responsive wp-image-5526\" srcset=\"https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-a-beaker-assy1-200x167.jpg 200w, https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-a-beaker-assy1-400x333.jpg 400w, https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-a-beaker-assy1-600x500.jpg 600w, https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-a-beaker-assy1-800x667.jpg 800w, https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-a-beaker-assy1-1200x1000.jpg 1200w, https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-a-beaker-assy1.jpg 1427w\" sizes=\"(max-width: 640px) 100vw, 800px\" \/><\/span><\/div><\/div><\/div><\/div><\/div>\n<\/div><\/div><\/div><div class=\"fusion-panel panel-default fusion-faq-post fusion-faq-post-5486 ultrasonic-homogenizer\"><span class=\"entry-title rich-snippet-hidden\">What is the difference between replaceable and solid ultrasonic probe tips?<\/span><span class=\"vcard rich-snippet-hidden\"><span class=\"fn\"><a href=\"https:\/\/www.sinosonics.com\/es\/author\/sino_sonics\/\" title=\"Entradas de Sino_Sonics\" rel=\"author\">Sino_Sonics<\/a><\/span><\/span><span class=\"updated rich-snippet-hidden\">2026-02-19T13:55:57+08:00<\/span><div class=\"panel-heading\"><h4 id=\"faq_1-5486\" class=\"panel-title toggle\"><a data-toggle=\"collapse\" class=\"collapsed\" data-parent=\"#accordian-1\" data-target=\"#collapse-1-5486\" href=\"#collapse-1-5486\" aria-expanded=\"false\"><div class=\"fusion-toggle-icon-wrapper\"><div class=\"fusion-toggle-icon-wrapper-main\"><div class=\"fusion-toggle-icon-wrapper-sub\"><i class=\"fa-fusion-box active-icon awb-icon-minus\" aria-hidden=\"true\"><\/i><i class=\"fa-fusion-box inactive-icon awb-icon-plus\" aria-hidden=\"true\"><\/i><\/div><\/div><\/div><div class=\"fusion-toggle-heading\">What is the difference between replaceable and solid ultrasonic probe tips?<\/div><\/a><\/h4><\/div><div id=\"collapse-1-5486\" aria-labelledby=\"faq_1-5486\" class=\"panel-collapse collapse\"><div class=\"panel-body toggle-content post-content\"><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1-9 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-stretch fusion-flex-content-wrap\" style=\"width:104% !important;max-width:104% !important;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-14 fusion_builder_column_3_5 3_5 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:60%;--awb-flex-grow:0;--awb-flex-shrink:0;--awb-margin-top-large:0px;--awb-spacing-right-large:3.2%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:3.2%;--awb-width-medium:60%;--awb-order-medium:0;--awb-flex-grow-medium:0;--awb-flex-shrink-medium:0;--awb-spacing-right-medium:3.2%;--awb-spacing-left-medium:3.2%;--awb-width-small:100%;--awb-order-small:0;--awb-flex-grow-small:0;--awb-flex-shrink-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-reading-box-container reading-box-container-10\" style=\"--awb-title-color:#0d244c;--awb-margin-top:0px;--awb-margin-bottom:30px;\"><div class=\"reading-box\" style=\"background-color:#f9f9fb;border-width:1px;border-color:rgba(226,226,226,0);border-style:solid;\"><div class=\"reading-box-additional\">\n<div class=\"grid__item\">\n<p data-start=\"102\" data-end=\"271\"><strong data-start=\"102\" data-end=\"128\">Replaceable tip probes<\/strong> are typically used for aqueous samples. These probes have a threaded, removable tip that can be replaced once worn, reducing maintenance cost.<\/p>\n<p data-start=\"273\" data-end=\"607\">However, when processing samples containing organic solvents, alcohols, or other low surface tension liquids, fluid can penetrate the threaded interface\u2014regardless of how tightly it is assembled. Once liquid enters the internal joint, it may loosen the connection, affect acoustic transmission, and potentially overload the generator.<\/p>\n<p data-start=\"609\" data-end=\"923\">For solvent-based or low surface tension applications, a <strong data-start=\"666\" data-end=\"691\">solid one-piece probe<\/strong> is strongly recommended. Solid probes have no threaded interface, providing improved structural integrity, better acoustic coupling, and higher operational reliability. Solid probes can be used for both aqueous and solvent systems.<\/p>\n<\/div>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-15 fusion_builder_column_2_5 2_5 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:40%;--awb-flex-grow:0;--awb-flex-shrink:0;--awb-margin-top-large:0px;--awb-spacing-right-large:4.8%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:4.8%;--awb-width-medium:40%;--awb-order-medium:0;--awb-flex-grow-medium:0;--awb-flex-shrink-medium:0;--awb-spacing-right-medium:4.8%;--awb-spacing-left-medium:4.8%;--awb-width-small:100%;--awb-order-small:0;--awb-flex-grow-small:0;--awb-flex-shrink-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-image-element\" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\"fusion-imageframe imageframe-none imageframe-5 hover-type-none\" style=\"border-radius:6px;\"><img decoding=\"async\" width=\"788\" height=\"411\" alt=\"replaceable vs solid ultrasonic probe tip comparison\" title=\"Replaceable vs Solid Ultrasonic Probe Tip\" src=\"https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-replacement-ultrasonic-probe.jpg\" class=\"img-responsive wp-image-5508\" srcset=\"https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-replacement-ultrasonic-probe-200x104.jpg 200w, https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-replacement-ultrasonic-probe-400x209.jpg 400w, https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-replacement-ultrasonic-probe-600x313.jpg 600w, https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-replacement-ultrasonic-probe.jpg 788w\" sizes=\"(max-width: 640px) 100vw, 600px\" \/><\/span><\/div><\/div><\/div><\/div><\/div>\n<\/div><\/div><\/div><div class=\"fusion-panel panel-default fusion-faq-post fusion-faq-post-5542 ultrasonic-homogenizer\"><span class=\"entry-title rich-snippet-hidden\">Does an ultrasonic converter require cooling during operation?<\/span><span class=\"vcard rich-snippet-hidden\"><span class=\"fn\"><a href=\"https:\/\/www.sinosonics.com\/es\/author\/sino_sonics\/\" title=\"Entradas de Sino_Sonics\" rel=\"author\">Sino_Sonics<\/a><\/span><\/span><span class=\"updated rich-snippet-hidden\">2026-02-19T13:59:13+08:00<\/span><div class=\"panel-heading\"><h4 id=\"faq_1-5542\" class=\"panel-title toggle\"><a data-toggle=\"collapse\" class=\"collapsed\" data-parent=\"#accordian-1\" data-target=\"#collapse-1-5542\" href=\"#collapse-1-5542\" aria-expanded=\"false\"><div class=\"fusion-toggle-icon-wrapper\"><div class=\"fusion-toggle-icon-wrapper-main\"><div class=\"fusion-toggle-icon-wrapper-sub\"><i class=\"fa-fusion-box active-icon awb-icon-minus\" aria-hidden=\"true\"><\/i><i class=\"fa-fusion-box inactive-icon awb-icon-plus\" aria-hidden=\"true\"><\/i><\/div><\/div><\/div><div class=\"fusion-toggle-heading\">Does an ultrasonic converter require cooling during operation?<\/div><\/a><\/h4><\/div><div id=\"collapse-1-5542\" aria-labelledby=\"faq_1-5542\" class=\"panel-collapse collapse\"><div class=\"panel-body toggle-content post-content\"><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1-10 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-stretch fusion-flex-content-wrap\" style=\"width:104% !important;max-width:104% !important;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-16 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-padding-right:0px;--awb-padding-left:0px;--awb-bg-size:cover;--awb-width-large:50%;--awb-flex-grow:0;--awb-flex-shrink:0;--awb-margin-top-large:0px;--awb-spacing-right-large:3.84%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:3.84%;--awb-width-medium:50%;--awb-order-medium:0;--awb-flex-grow-medium:0;--awb-flex-shrink-medium:0;--awb-spacing-right-medium:3.84%;--awb-spacing-left-medium:3.84%;--awb-width-small:100%;--awb-order-small:0;--awb-flex-grow-small:0;--awb-flex-shrink-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-reading-box-container reading-box-container-11\" style=\"--awb-title-color:#0d244c;--awb-margin-top:0px;--awb-margin-bottom:30px;\"><div class=\"reading-box\" style=\"background-color:#f9f9fb;border-width:1px;border-color:rgba(226,226,226,0);border-style:solid;\"><div class=\"reading-box-additional\">\n<div class=\"grid__item\">\n<p data-start=\"243\" data-end=\"487\">During long sonication cycles, heat generated at the probe tip travels upward through the horn to the converter. If excessive heat builds up, it can damage the piezoelectric elements and reduce the lifespan of the ultrasonic homogenizer system.<\/p>\n<p data-start=\"489\" data-end=\"749\">For continuous or heavy-duty applications, proper cooling is essential. Industrial ultrasonic converters are typically designed with integrated cooling fans or forced-air ventilation to maintain stable operating temperatures and ensure reliable 24\/7 operation.<\/p>\n<p data-start=\"751\" data-end=\"873\">Insufficient cooling may lead to reduced performance, automatic overload protection, or permanent damage to the converter.<\/p>\n<\/div>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-17 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-padding-right:0px;--awb-padding-left:0px;--awb-bg-size:cover;--awb-width-large:50%;--awb-flex-grow:0;--awb-flex-shrink:0;--awb-margin-top-large:0px;--awb-spacing-right-large:3.84%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:3.84%;--awb-width-medium:50%;--awb-order-medium:0;--awb-flex-grow-medium:0;--awb-flex-shrink-medium:0;--awb-spacing-right-medium:3.84%;--awb-spacing-left-medium:3.84%;--awb-width-small:100%;--awb-order-small:0;--awb-flex-grow-small:0;--awb-flex-shrink-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-image-element\" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\"fusion-imageframe imageframe-none imageframe-6 hover-type-none\" style=\"border-radius:6px;\"><img decoding=\"async\" width=\"1024\" height=\"683\" alt=\"ultrasonic converter with built-in cooling fan for sonicator system\" title=\"Ultrasonic Converter with Cooling Fan \u2013 Sino Sonics\" src=\"https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/Laboratory-Ultrasonic-Homogenizer-4-1024x683.jpg\" class=\"img-responsive wp-image-5017\" srcset=\"https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/Laboratory-Ultrasonic-Homogenizer-4-200x133.jpg 200w, https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/Laboratory-Ultrasonic-Homogenizer-4-400x267.jpg 400w, https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/Laboratory-Ultrasonic-Homogenizer-4-600x400.jpg 600w, https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/Laboratory-Ultrasonic-Homogenizer-4-800x533.jpg 800w, https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/Laboratory-Ultrasonic-Homogenizer-4-1200x800.jpg 1200w, https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/Laboratory-Ultrasonic-Homogenizer-4.jpg 1920w\" sizes=\"(max-width: 640px) 100vw, 800px\" \/><\/span><\/div><\/div><\/div><\/div><\/div>\n<\/div><\/div><\/div><div class=\"fusion-panel panel-default fusion-faq-post fusion-faq-post-5515 ultrasonic-homogenizer\"><span class=\"entry-title rich-snippet-hidden\">How to safely clamp an ultrasonic converter without damaging the transducer?<\/span><span class=\"vcard rich-snippet-hidden\"><span class=\"fn\"><a href=\"https:\/\/www.sinosonics.com\/es\/author\/sino_sonics\/\" title=\"Entradas de Sino_Sonics\" rel=\"author\">Sino_Sonics<\/a><\/span><\/span><span class=\"updated rich-snippet-hidden\">2026-02-19T14:02:19+08:00<\/span><div class=\"panel-heading\"><h4 id=\"faq_1-5515\" class=\"panel-title toggle\"><a data-toggle=\"collapse\" class=\"collapsed\" data-parent=\"#accordian-1\" data-target=\"#collapse-1-5515\" href=\"#collapse-1-5515\" aria-expanded=\"false\"><div class=\"fusion-toggle-icon-wrapper\"><div class=\"fusion-toggle-icon-wrapper-main\"><div class=\"fusion-toggle-icon-wrapper-sub\"><i class=\"fa-fusion-box active-icon awb-icon-minus\" aria-hidden=\"true\"><\/i><i class=\"fa-fusion-box inactive-icon awb-icon-plus\" aria-hidden=\"true\"><\/i><\/div><\/div><\/div><div class=\"fusion-toggle-heading\">How to safely clamp an ultrasonic converter without damaging the transducer?<\/div><\/a><\/h4><\/div><div id=\"collapse-1-5515\" aria-labelledby=\"faq_1-5515\" class=\"panel-collapse collapse\"><div class=\"panel-body toggle-content post-content\"><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1-11 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-stretch fusion-flex-content-wrap\" style=\"width:104% !important;max-width:104% !important;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-18 fusion_builder_column_3_5 3_5 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:60%;--awb-flex-grow:0;--awb-flex-shrink:0;--awb-margin-top-large:0px;--awb-spacing-right-large:3.2%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:3.2%;--awb-width-medium:60%;--awb-order-medium:0;--awb-flex-grow-medium:0;--awb-flex-shrink-medium:0;--awb-spacing-right-medium:3.2%;--awb-spacing-left-medium:3.2%;--awb-width-small:100%;--awb-order-small:0;--awb-flex-grow-small:0;--awb-flex-shrink-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-reading-box-container reading-box-container-12\" style=\"--awb-title-color:#0d244c;--awb-margin-top:0px;--awb-margin-bottom:30px;\"><div class=\"reading-box\" style=\"background-color:#f9f9fb;border-width:1px;border-color:rgba(226,226,226,0);border-style:solid;\"><div class=\"reading-box-additional\">\n<div class=\"grid__item\">\n<p data-start=\"187\" data-end=\"432\">Improper clamping can damage the converter, reduce performance, and void the warranty. The clamp must never be attached to the active vibrating section of the converter or horn, as this area experiences longitudinal oscillation during operation.<\/p>\n<p data-start=\"434\" data-end=\"609\">Clamping on a vibrating section restricts movement, alters resonance characteristics, increases mechanical stress, and may cause overheating or internal piezoelectric failure.<\/p>\n<p data-start=\"611\" data-end=\"766\">The converter should only be clamped at the designated mounting area (non-vibrating section), typically near the nodal point specified by the manufacturer.<\/p>\n<p data-start=\"768\" data-end=\"862\">Using a properly designed stand or enclosure ensures correct positioning and stable operation.<\/p>\n<\/div>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-19 fusion_builder_column_2_5 2_5 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:40%;--awb-flex-grow:0;--awb-flex-shrink:0;--awb-margin-top-large:0px;--awb-spacing-right-large:4.8%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:4.8%;--awb-width-medium:40%;--awb-order-medium:0;--awb-flex-grow-medium:0;--awb-flex-shrink-medium:0;--awb-spacing-right-medium:4.8%;--awb-spacing-left-medium:4.8%;--awb-width-small:100%;--awb-order-small:0;--awb-flex-grow-small:0;--awb-flex-shrink-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-image-element\" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\"fusion-imageframe imageframe-none imageframe-7 hover-type-none\" style=\"border-radius:6px;\"><img decoding=\"async\" width=\"780\" height=\"750\" alt=\"Proper vs improper clamping position on ultrasonic converter transducer\" title=\"How to Clamp an Ultrasonic Converter Correctly\" src=\"https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-how-to-clamp-a-converter-v2.jpg\" class=\"img-responsive wp-image-5516\" srcset=\"https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-how-to-clamp-a-converter-v2-200x192.jpg 200w, https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-how-to-clamp-a-converter-v2-400x385.jpg 400w, https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-how-to-clamp-a-converter-v2-600x577.jpg 600w, https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/05\/210522-blog-how-to-clamp-a-converter-v2.jpg 780w\" sizes=\"(max-width: 640px) 100vw, 600px\" \/><\/span><\/div><\/div><\/div><\/div><\/div>\n<\/div><\/div><\/div><div class=\"fusion-panel panel-default fusion-faq-post fusion-faq-post-5545 ultrasonic-homogenizer\"><span class=\"entry-title rich-snippet-hidden\">What is a booster horn and when is it required in an ultrasonic system?<\/span><span class=\"vcard rich-snippet-hidden\"><span class=\"fn\"><a href=\"https:\/\/www.sinosonics.com\/es\/author\/sino_sonics\/\" title=\"Entradas de Sino_Sonics\" rel=\"author\">Sino_Sonics<\/a><\/span><\/span><span class=\"updated rich-snippet-hidden\">2026-02-19T14:04:11+08:00<\/span><div class=\"panel-heading\"><h4 id=\"faq_1-5545\" class=\"panel-title toggle\"><a data-toggle=\"collapse\" class=\"collapsed\" data-parent=\"#accordian-1\" data-target=\"#collapse-1-5545\" href=\"#collapse-1-5545\" aria-expanded=\"false\"><div class=\"fusion-toggle-icon-wrapper\"><div class=\"fusion-toggle-icon-wrapper-main\"><div class=\"fusion-toggle-icon-wrapper-sub\"><i class=\"fa-fusion-box active-icon awb-icon-minus\" aria-hidden=\"true\"><\/i><i class=\"fa-fusion-box inactive-icon awb-icon-plus\" aria-hidden=\"true\"><\/i><\/div><\/div><\/div><div class=\"fusion-toggle-heading\">What is a booster horn and when is it required in an ultrasonic system?<\/div><\/a><\/h4><\/div><div id=\"collapse-1-5545\" aria-labelledby=\"faq_1-5545\" class=\"panel-collapse collapse\"><div class=\"panel-body toggle-content post-content\"><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1-12 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-stretch fusion-flex-content-wrap\" style=\"width:104% !important;max-width:104% !important;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-20 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-padding-right:0px;--awb-padding-left:0px;--awb-bg-size:cover;--awb-width-large:100%;--awb-flex-grow:0;--awb-flex-shrink:0;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-flex-grow-medium:0;--awb-flex-shrink-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-flex-grow-small:0;--awb-flex-shrink-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-reading-box-container reading-box-container-13\" style=\"--awb-title-color:#0d244c;--awb-margin-top:0px;--awb-margin-bottom:30px;\"><div class=\"reading-box\" style=\"background-color:#f9f9fb;border-width:1px;border-color:rgba(226,226,226,0);border-style:solid;\"><div class=\"reading-box-additional\">\n<div class=\"grid__item\">\n<p data-start=\"116\" data-end=\"366\">A booster horn is used to increase or decrease the amplitude delivered from the ultrasonic converter to the probe. It changes the vibration ratio between the converter and the horn, allowing higher intensity output without increasing generator power.<\/p>\n<p data-start=\"368\" data-end=\"600\">For example, a 2:1 booster can double the amplitude of a 1\u201d probe, significantly reducing processing time when working with larger volumes. A 1 liter sample can often be processed much faster when a properly matched booster is used.<\/p>\n<p data-start=\"602\" data-end=\"765\">Small diameter probes already operate at high intensity and should not be used with high-gain boosters, as excessive amplitude may cause probe fatigue or cracking.<\/p>\n<p data-start=\"767\" data-end=\"897\">Boosters are typically recommended for high-volume processing, viscous materials, or applications requiring higher energy density.<\/p>\n<\/div>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div><\/div><\/div>\n<\/div><\/div><\/div><div class=\"fusion-panel panel-default fusion-faq-post fusion-faq-post-5551 ultrasonic-homogenizer\"><span class=\"entry-title rich-snippet-hidden\">Why does ultrasonic sonication produce noise and how can it be reduced?<\/span><span class=\"vcard rich-snippet-hidden\"><span class=\"fn\"><a href=\"https:\/\/www.sinosonics.com\/es\/author\/sino_sonics\/\" title=\"Entradas de Sino_Sonics\" rel=\"author\">Sino_Sonics<\/a><\/span><\/span><span class=\"updated rich-snippet-hidden\">2026-02-19T14:07:53+08:00<\/span><div class=\"panel-heading\"><h4 id=\"faq_1-5551\" class=\"panel-title toggle\"><a data-toggle=\"collapse\" class=\"collapsed\" data-parent=\"#accordian-1\" data-target=\"#collapse-1-5551\" href=\"#collapse-1-5551\" aria-expanded=\"false\"><div class=\"fusion-toggle-icon-wrapper\"><div class=\"fusion-toggle-icon-wrapper-main\"><div class=\"fusion-toggle-icon-wrapper-sub\"><i class=\"fa-fusion-box active-icon awb-icon-minus\" aria-hidden=\"true\"><\/i><i class=\"fa-fusion-box inactive-icon awb-icon-plus\" aria-hidden=\"true\"><\/i><\/div><\/div><\/div><div class=\"fusion-toggle-heading\">Why does ultrasonic sonication produce noise and how can it be reduced?<\/div><\/a><\/h4><\/div><div id=\"collapse-1-5551\" aria-labelledby=\"faq_1-5551\" class=\"panel-collapse collapse\"><div class=\"panel-body toggle-content post-content\"><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1-13 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-stretch fusion-flex-content-wrap\" style=\"width:104% !important;max-width:104% !important;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-21 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-padding-right:0px;--awb-padding-left:0px;--awb-bg-size:cover;--awb-width-large:50%;--awb-flex-grow:0;--awb-flex-shrink:0;--awb-margin-top-large:0px;--awb-spacing-right-large:3.84%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:3.84%;--awb-width-medium:50%;--awb-order-medium:0;--awb-flex-grow-medium:0;--awb-flex-shrink-medium:0;--awb-spacing-right-medium:3.84%;--awb-spacing-left-medium:3.84%;--awb-width-small:100%;--awb-order-small:0;--awb-flex-grow-small:0;--awb-flex-shrink-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-reading-box-container reading-box-container-14\" style=\"--awb-title-color:#0d244c;--awb-margin-top:0px;--awb-margin-bottom:30px;\"><div class=\"reading-box\" style=\"background-color:#f9f9fb;border-width:1px;border-color:rgba(226,226,226,0);border-style:solid;\"><div class=\"reading-box-additional\">\n<p data-start=\"108\" data-end=\"313\">Ultrasonic homogenization generates high-frequency noise, typically exceeding 85 dB during operation. Prolonged exposure to this noise may cause discomfort and is not recommended without proper protection.<\/p>\n<p data-start=\"315\" data-end=\"504\">A sound enclosure can significantly reduce operating noise (typically by up to 20 dB, depending on configuration and environment), creating a safer and more comfortable working environment.<\/p>\n<p data-start=\"506\" data-end=\"684\">Our sound enclosure is designed to securely support the converter and probe assembly, eliminating the need for an additional stand or clamp while improving operational stability.<\/p>\n<p data-start=\"686\" data-end=\"789\">Multiple enclosure models are available to accommodate different system configurations and accessories.<\/p>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-22 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-padding-right:0px;--awb-padding-left:0px;--awb-bg-size:cover;--awb-width-large:50%;--awb-flex-grow:0;--awb-flex-shrink:0;--awb-margin-top-large:0px;--awb-spacing-right-large:3.84%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:3.84%;--awb-width-medium:50%;--awb-order-medium:0;--awb-flex-grow-medium:0;--awb-flex-shrink-medium:0;--awb-spacing-right-medium:3.84%;--awb-spacing-left-medium:3.84%;--awb-width-small:100%;--awb-order-small:0;--awb-flex-grow-small:0;--awb-flex-shrink-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-image-element\" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\"fusion-imageframe imageframe-none imageframe-8 hover-type-none\" style=\"border-radius:6px;\"><img decoding=\"async\" width=\"1024\" height=\"680\" alt=\"Ultrasonic homogenizer sound enclosure cabinet for laboratory noise reduction\" title=\"25khz-integrated-ultrasonic-homogenizer-processor-02\" src=\"https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/11\/25khz-integrated-ultrasonic-homogenizer-processor-02-1024x680.jpg\" class=\"img-responsive wp-image-6230\" srcset=\"https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/11\/25khz-integrated-ultrasonic-homogenizer-processor-02-200x133.jpg 200w, https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/11\/25khz-integrated-ultrasonic-homogenizer-processor-02-400x266.jpg 400w, https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/11\/25khz-integrated-ultrasonic-homogenizer-processor-02-600x398.jpg 600w, https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/11\/25khz-integrated-ultrasonic-homogenizer-processor-02-800x531.jpg 800w, https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/11\/25khz-integrated-ultrasonic-homogenizer-processor-02-1200x797.jpg 1200w, https:\/\/www.sinosonics.com\/wp-content\/uploads\/2021\/11\/25khz-integrated-ultrasonic-homogenizer-processor-02.jpg 1280w\" sizes=\"(max-width: 640px) 100vw, 800px\" \/><\/span><\/div><\/div><\/div><\/div><\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":3496,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-5555","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.sinosonics.com\/es\/wp-json\/wp\/v2\/pages\/5555","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.sinosonics.com\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.sinosonics.com\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.sinosonics.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.sinosonics.com\/es\/wp-json\/wp\/v2\/comments?post=5555"}],"version-history":[{"count":3,"href":"https:\/\/www.sinosonics.com\/es\/wp-json\/wp\/v2\/pages\/5555\/revisions"}],"predecessor-version":[{"id":8239,"href":"https:\/\/www.sinosonics.com\/es\/wp-json\/wp\/v2\/pages\/5555\/revisions\/8239"}],"up":[{"embeddable":true,"href":"https:\/\/www.sinosonics.com\/es\/wp-json\/wp\/v2\/pages\/3496"}],"wp:attachment":[{"href":"https:\/\/www.sinosonics.com\/es\/wp-json\/wp\/v2\/media?parent=5555"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}